新一代PU516模拟量输入模块适合风机、泵类负载使用。秉承F500的优良特性,操作简单,并全面提升各种功能:新开发的节能监视功能让节能效果一目了然。新增V/F曲线5点可调整功能。采用长寿命设计(设计寿命10年),维护简单,使用安心,同时还具有的寿命診断及预警功能。内置噪声滤波器,并带有浪涌电流吸收回路新增了RS-485端子,增加支持Modbus-RTU (Binary)协议。反向起动功能,再生制动回避功能,还增加了PTC热电阻输入。

PU516
PU516 3BSE013064R1 应查看步进电机的绝缘,最好在接线之前完成对电机的单体调试查看,当电机契合现行标准要求时,再接外部线。一般低压电机的绝缘电阻要求大于0.5MΩ,摇表使用500V。但是,直流电机的励磁绕组和电枢绕组如果彼此直接反,就可能使电机电枢带电时,励磁绕组不带电而失磁,使电机空载时可能飞车,重载时烧坏转子。因而,直流电机的电枢绕组和励磁绕组的外部接线肯定不可彼此直接错。电机的外接线。电机接外部电线之前,应先查看端盖内的各个绕组引出端是否有松动现象,当内部引出线的压接螺丝上紧之后,才干按要求的接线办法连接短路片,并压接外部线。

PU516
其功率范围:0.75KW~630KW (三相380V,FR-F740-CH系列)PLC的远程输出功能、标准配备更多的输入输出端子、简易磁通矢量控制功能、多泵控制功能、三角波(摆频)功能等更多功能特性。PU516功能:广受好评的励磁控制功能进一步改良,节能效果一目了然适合风机、泵类负载使用:V/F曲线5点可调,PID功能更加丰富,间停电再启动功能得到更新,时停电再启动功能,反转时直接启动功能,再生制动回避功能,PTC热电阻输入,工频切换顺序控制。

PU516
The new generation PU516 analog input module is suitable for use with loads such as fans and pumps. Adhering to the excellent characteristics of the F500, it is easy to operate and comprehensively improves various functions: the newly developed energy-saving monitoring function makes the energy-saving effect clear at a glance. New V/F curve with 5 adjustable points. Adopting a long lifespan design (with a design lifespan of 10 years), it is easy to maintain, safe to use, and also has life diagnosis and warning functions. Equipped with a built-in noise filter and a surge current absorption circuit, an RS-485 terminal has been added to support the Modbus RTU (Binary) protocol. Reverse start function, regenerative braking avoidance function, and added PTC thermal resistance input.

PU516
PU516 3BSE013064R1 should check the insulation of the stepper motor. It is best to complete the individual debugging and inspection of the motor before wiring. When the motor meets the current standard requirements, external wires should be connected. The insulation resistance of general low-voltage motors is required to be greater than 0.5M Ω, and the megger should use 500V. However, if the excitation winding and armature winding of a DC motor are directly opposite to each other, it may cause the excitation winding to lose excitation when the motor armature is energized, which may cause the motor to spin when unloaded and burn out the rotor when overloaded. Therefore, the external wiring of the armature winding and excitation winding of a DC motor must not be directly wrong with each other. External wiring of the motor. Before connecting the motor to external wires, it is necessary to check whether the outgoing terminals of each winding inside the end cover are loose. Only after the crimping screws of the internal outgoing wires are tightened can the short circuit strips be connected according to the required wiring method and the external wires be crimped

PU516
Its power range: 0.75KW~630KW (three-phase 380V, FR-F740-CH series) PLC’s remote output function, standard equipped with more input and output terminals, simple magnetic flux vector control function, multi pump control function, triangular wave (swing) function, and more functional features. PU516 function: The widely acclaimed excitation control function has been further improved, and the energy-saving effect is clear at a glance. It is suitable for use with loads such as fans and pumps. The V/F curve is adjustable at 5 points, and the PID function is more diverse. The power outage restart function has been updated, including power outage restart function, direct start function during reverse rotation, regenerative braking avoidance function, PTC thermal resistance input, and power frequency switching sequence control
There are no reviews yet.