BENTLY 990-04-50-01-00 变送器 反向连接可以通过流量测量系统

In stock

品牌:BENTLY

型号:990-04-50-01-00

名称:变送器

质保:一年

  • 电话/Phone:17350011025 (微信同号)
  • 邮箱/Email:1713556114@qq.com
  • QQ:1713556114

BENTLY 990-04-50-01-00 变送器力变送器塞的产生主要是在生产过程中产生的。如果压力变送器插塞,变送器的输出值会变慢, 甚至没有输出。经过长时间的研究,发现这一问题的原因在于压力转换器生产、检测到颗粒或灰尘长时间积累,粒子不断增长、凝固,导致压力管的插入,因此,力变送器不能正常使用。解决问题的方法是拆除压力管,清除压力管中的颗粒物,恢复压力管的平稳流动。压力变送器弓|压管高低压错接:力变送器的反向连接可以通过流量测量系统、差压变送器和初级元件的孔板来演示。当压力变送器投入使用时,差压变送器上的读数会浮在零点,不会有较大的上升,甚至下降。通过观察在使用中的节流孔板和流量测量系统的输出值,可以看出输出值在零以下,这是由于压力变送器高压管道关闭或部分部位漏气造成的。励变送器高压管道与低压管道处于反向位置。发射机坏了。通过检查发射机,如果没有问题,输出量随着输入量的变化而改变,并且引压管亦没有堵塞现象,那么,该问题就是高压引压管和低压引压管的位置接错了。解决方案,通过改变孔板位置即可。对于智能压力变送器我们可以改变检测部件和传输部件的位置,将他们的位置改变。

990-04-50-01-00

990-04-50-01-00

The generation of force transmitter plugs for BENTLY 990-04-50-01-00 transmitters is mainly during the production process. If the pressure transmitter is plugged, the output value of the transmitter will slow down or even have no output. After a long period of research, it was found that the reason for this problem is due to the production and detection of pressure converters, which accumulate particles or dust for a long time. The particles continue to grow and solidify, leading to the insertion of pressure pipes. Therefore, the force transmitter cannot be used normally. The solution to the problem is to remove the pressure pipe, remove the particles in the pressure pipe, and restore the smooth flow of the pressure pipe. Pressure transmitter bow | high and low pressure misconnection of pressure pipe: The reverse connection of force transmitter can be demonstrated through flow measurement system, differential pressure transmitter, and orifice plate of primary components. When the pressure transmitter is put into use, the reading on the differential pressure transmitter will float at zero and there will be no significant increase or even decrease. By observing the output values of the throttle orifice plate and flow measurement system in use, it can be seen that the output values are below zero, which is caused by the closure of the high-pressure pipeline of the pressure transmitter or leakage in some parts. The high-pressure pipeline and low-pressure pipeline of the excitation transmitter are in the opposite position. The transmitter is broken. By checking the transmitter, if there is no problem, the output changes with the input quantity, and there is no blockage in the impulse tube, then the problem is that the position of the high-voltage and low-voltage impulse tubes is connected incorrectly. The solution is to change the position of the orifice plate. For intelligent pressure transmitters, we can change the positions of the detection and transmission components by changing their positions.

Customers reviews

There are no reviews yet.

Be the first to review “BENTLY 990-04-50-01-00 变送器 反向连接可以通过流量测量系统”

您的邮箱地址不会被公开。 必填项已用 * 标注

Search for products

Back to Top
Product has been added to your cart