16通道继电器模块是一个全高模块, 它提供16个继电器输出。你可以放置任意数的16-右侧任何插槽中的通道继电器模块瞬态数据接口模块。16通
道继电器模块的每个输出可以是独立编程以执行表决逻辑。模块的每个继电器都包括报警驱动逻辑。报警驱动逻辑的编程使用AND和or逻辑and可以使用以下内容:n报警输入(警报和危险状态)不太好来自任何监控通道的n个单独的测量变量或者机架中监视器通道的任意组合您可以使用3500框架对报警驱动进行编程配置软件。n 16通道继电器模块需要3500框架配置,版本3.3或更 高版本。16通道继电器模块需要3500数据采集软件, 2.40或更高版本。16通道继电器模块需要3500数据显示软件,版本=1 .40或更高。n以倍数订购时认证选项(02), 3500显示器是通过2区标准认证,包括ATEX和北美地区。n 2区标准规定增加更高电压下的间距要求。16通道继电器模块不满足这些间距要求。因此,与倍数-起订购的模块批准选项仅限于较低的电压比那些与其他批准选项。n使用更高的电压违反了与以下相关的危险区域证书多重批准选项。北美第2部分标准与仅限CSA的批准相关联选项(-01)已降级为30Vrms符合61010- 1型式试验要求。n如果1 6通道继电器模块是功能安全(SIL)系统功能安全证书要求受限电压。更高的电压不会允许用于功能安全(SIL)系统。
The 16 channel relay module is a full height module that provides 16 relay outputs. You can place any number of channel relay modules transient data interface modules in any slot on the right side of the 16. 16 way
Each output of the relay module can be independently programmed to execute voting logic. Each relay in the module includes alarm drive logic. The programming of alarm driver logic uses AND and OR logic, and the following content can be used: n Alarm inputs (alarm and danger states) are not very good. n individual measurement variables from any monitoring channel or any combination of monitor channels in the rack. You can use the 3500 framework to program and configure the alarm driver software. The 16 channel relay module requires a 3500 rack configuration, version 3.3 or higher. The 16 channel relay module requires 3500 data acquisition software, version 2.40 or higher. The 16 channel relay module requires 3500 data display software, version=1.40 or higher. When ordering in multiples (02), the 3500 monitor is certified to Zone 2 standards, including ATEX and North America. The standard for Zone 2 specifies the addition of spacing requirements at higher voltages. The 16 channel relay module does not meet these spacing requirements. Therefore, the module approval options ordered with multiples are limited to those with lower voltage ratios compared to other approval options. The use of higher voltage violates multiple approval options for hazardous area certificates related to the following. The North American Part 2 standard and CSA only approval related option (-01) have been downgraded to 30Vrms to meet the 61010-1 type test requirements. If the 1-6 channel relay module is a Functional Safety (SIL) system, the Functional Safety Certificate requires limited voltage. Higher voltages are not allowed for use in functional safety (SIL) systems.
专业销售世界各大电气品牌产品产品海外直接采购,正品库存,价格优惠售后保修,型号齐全,一样的产品,不一样的价格与服务。大量供应原装进口DCS系统配件,PLC系统配件。主营:ABB、GE发那科、Bentl本特利、Triconex英维思、Woodward伍德沃德、Foxboro福克斯波罗、Westinghouse西屋/Emerson艾默生、Reliance瑞恩、SchneiderModicon施耐德莫迪康、A-B、HIMA黑马、Motorola摩托罗拉、Kollmorgen科尔摩根Bosch/Rexroth/博世力上乐,NI,YOKOGAWA横河,等各大品牌的DCS系统配件,机器人系统配件,大型伺服系统停产备件
There are no reviews yet.